Friday, January 14, 2011

Converting A.c. to D.c.

Diodes



Circuit symbol:



Diodes are kinds of device that allow current flow only in one direction in circuits. (The arrow of the circuit symbol shows the direction in which the current can flow.) Thus, only half of the cycles of alternating current can pass from the diodes. You can easily convert alternating current into the direct current with this device. Diodes are the electrical version of a valve and early diodes were actually called valves.

Following circuit shows the usage of diodes.

In the given circuit, D1 let current flow however, D2 does not let current flow.



Forward Voltage Drop

Electricity uses up a little energy pushing its way through the diode, rather like a person pushing through a door with a spring. This means that there is a small voltage across a conducting diode, it is called the forward voltage drop and is about 0.7V for all normal diodes which are made from silicon. The forward voltage drop of a diode is almost constant whatever the current passing through the diode so they have a very steep characteristic (current-voltage graph).

Reverse Voltage

When a reverse voltage is applied a perfect diode does not conduct, but all real diodes leak a very tiny current of a few µA or less. This can be ignored in most circuits because it will be very much smaller than the current flowing in the forward direction. However, all diodes have a maximum reverse voltage (usually 50V or more) and if this is exceeded the diode will fail and pass a large current in the reverse direction, this is called breakdown.

Ordinary diodes can be split into two types: Signal diodes which pass small currents of 100mA or less and Rectifier diodes which can pass large currents. In addition there are LEDs and Zener diodes


Rectifier diodes (large current)

Rectifier diodes are used in power supplies to convert alternating current (AC) to direct current (DC), a process called rectification. They are also used elsewhere in circuits where a large current must pass through the diode.

All rectifier diodes are made from silicon and therefore have a forward voltage drop of 0.7V. The table shows maximum current and maximum reverse voltage for some popular rectifier diodes. The 1N4001 is suitable for most low voltage circuits with a current of less than 1A.


Zener diodes



Circuit symbol:



Zener diodes are used to maintain a fixed voltage. They are designed to 'breakdown' in a reliable and non-destructive way so that they can be used in reverse to maintain a fixed voltage across their terminals. The diagram shows how they are connected, with a resistor in series to limit the current.

Zener diodes can be distinguished from ordinary diodes by their code and breakdown voltage which are printed on them. Zener diode codes begin BZX... or BZY... Their breakdown voltage is printed with V in place of a decimal point, so 4V7 means 4.7V for example.

Zener diodes are rated by their breakdown voltage and maximum power:

  • The minimum voltage available is 2.4V.
  • Power ratings of 400mW and 1.3W are common.






Bridge rectifiers

There are several ways of connecting diodes to make a rectifier to convert AC to DC. The bridge rectifier is one of them and it is available in special packages containing the four diodes required. Bridge rectifiers are rated by their maximum current and maximum reverse voltage. They have four leads or terminals: the two DC outputs are labelled + and -, the two AC inputs are labelled ~.

The diagram shows the operation of a bridge rectifier as it converts AC to DC. Notice how alternate pairs of diodes conduct.




Cathode Ray Oscilloscope

The cathode-ray oscilloscope (CRO) is a common laboratory instrument that provides accurate time and aplitude measurements of voltage signals over a wide range of frequencies. Its reliability, stability, and ease of operation make it suitable as a general purpose laboratory instrument. The heart of the CRO is a cathode-ray tube shown schematically in Fig. 1.


The cathode ray is a beam of electrons which are emitted by the heated cathode (negative electrode) and accelerated toward the fluorescent screen. The assembly of the cathode, intensity grid, focus grid, and accelerating anode (positive electrode) is called an electron gun. Its purpose is to generate the electron beam and control its intensity and focus. Between the electron gun and the fluorescent screen are two pair of metal plates - one oriented to provide horizontal deflection of the beam and one pair oriented ot give vertical deflection to the beam. These plates are thus referred to as the horizontal and vertical deflection plates. The combination of these two deflections allows the beam to reach any portion of the fluorescent screen. Wherever the electron beam hits the screen, the phosphor is excited and light is emitted from that point. This coversion of electron energy into light allows us to write with points or lines of light on an otherwise darkened screen.

In the most common use of the oscilloscope the signal to be studied is first amplified and then applied to the vertical (deflection) plates to deflect the beam vertically and at the same time a voltage that increases linearly with time is applied to the horizontal (deflection) plates thus causing the beam to be deflected horizontally at a uniform (constant> rate. The signal applied to the verical plates is thus displayed on the screen as a function of time. The horizontal axis serves as a uniform time scale.

The linear deflection or sweep of the beam horizontally is accomplished by use of a sweep generator that is incorporated in the oscilloscope circuitry.

The voltage output of such a generator is that of a sawtooth wave as shown in Fig. 2. Application of one cycle of this voltage difference, which increases linearly with time, to the horizontal plates causes the beam to be deflected linearly with time across the tube face. When the voltage suddenly falls to zero, as at points (a) (b) (c), etc...., the end of each sweep - the beam flies back to its initial position. The horizontal deflection of the beam is repeated periodically, the frequency of this periodicity is adjustable by external controls.



CRO Operation:

A simplified block diagram of a typical oscilloscope is shown in Fig. 3. In general, the instrument is operated in the following manner. The signal to be displayed is amplified by the vertical amplifier and applied to the verical deflection plates of the CRT. A portion of the signal in the vertical amplifier is applied to the sweep trigger as a triggering signal. The sweep trigger then generates a pulse coincident with a selected point in the cycle of the triggering signal. This pulse turns on the sweep generator, initiating the sawtooth wave form.

The sawtooth wave is amplified by the horizontal amplifier and applied to the horizontal deflection plates. Usually, additional provisions signal are made for appliying an external triggering signal or utilizing the 60 Hz line for triggering. Also the sweep generator may be bypassed and an external signal applied directly to the horizontal amplifier.

CRO Controls

The controls available on most oscilloscopes provide a wide range of operating conditions and thus make the instrument especially versatile. Since many of these controls are common to most oscilloscopes a brief description of them follows.

Measurements of Voltage:

Consider the circuit in Fig. 4(a). The signal generator is used to produce a 1000 hertz sine wave. The AC voltmeter and the leads to the verticle input of the oscilloscope are connected across the generator's output. By adjusting the Horizontal Sweep time/cm and trigger, a steady trace of the sine wave may be displayed on the screen. The trace represents a plot of voltage vs. time, where the vertical deflection of the trace about the line of symmetry CD is proportional to the magnitude of the voltage at any instant of time.


To determine the size of the voltage signal appearing at the output of terminals of the signal generator, an AC (Alternating Current) voltmeter is connected in parallel across these terminals (Fig. 4a). The AC voltmeter is designed to read the dc "effective value" of the voltage. This effective value is also known as the "Root Mean Square value" (RMS) value of the voltage.

The peak or maximum voltage seen on the scope face (Fig. 4b) is Vm volts and is represented by the distance from the symmetry line CD to the maximum deflection. The relationship between the magnitude of the peak voltage displayed on the scope and the effective or RMS voltage (VRMS) read on the AC voltmeter is

VRMS = 0.707 Vm (for a sine or cosine wave).

Thus,



Agreement is expected between the voltage reading of the multimeter and that of the oscilloscope. For a symmetric wave (sine or cosine) the value of Vm may be taken as 1/2 the peak to peak signal Vpp

The variable sensitivity control a signal may be used to adjust the display to fill a concenient range of the scope face. In this position, the trace is no longer calibrated so that you can not just read the size of the signal by counting the number of divisions and multiplying by the scale factor. However, you can figure out what the new calibration is an use it as long as the variable control remains unchanged.

For more information on CRO and measurement of voltage, Visit:
Schoolphysics.co.uk
vsagar.com

Friday, January 7, 2011

Electromagnetic Induction



Electromagnetic Induction

Electromagnetic induction is the production of voltage across a conductor moving through a magnetic field. It underlies the operation of generators, all electric motors, transformers, induction motors, synchronous motors, solenoids, and most other electrical machines.

Michael Faraday is generally credited with the discovery of the induction phenomenon in 1831 though it may have been anticipated by the work of Francesco Zantedeschi in 1829.[citation needed] Around 1830[1] to 1832[2] Joseph Henry made a similar discovery, but did not publish his findings until later.

Laws of electromagnetism

Faraday's laws

English scientist Michael Faraday proposed three laws of electromagnetic induction:

(1) a changing magnetic field induces an electromagnetic force in a conductor;

(2) the electromagnetic force is proportional to the rate of change of the field;

(3) the direction of the induced electromagnetic force depends on the orientation of the field.

Lenz's law

The direction of an electromagnetically-induced current (generated by moving a magnet near a wire or by moving a wire in a magnetic field) will be such as to oppose the motion producing it.

This law is named after the German physicist Heinrich Friedrich Lenz (1804–1865), who announced it in 1833.


Alternate Current

Alternating Current is the movement of electrons in a wire backwards then forwards repeatedly and thus whose current constantly changes direction.In Europe this change repeats 50 times per second (or 50 Hz). In the USA, the frequency is 60 Hz.

AC is remarkably useful because it allows us to change electricity very easily using transformers which cannot work with DC.

The UK mains supply is about 230V. It has a frequency of 50Hz (50 hertz), which means that it changes direction and back again 50 times a second. The diagram shows an oscilloscope screen displaying the signal from an AC supply.




Alternate Current Generators

Regardless of size, all electrical generators, whether dc or ac, depend upon the principle of magnetic induction. An emf is induced in a coil as a result of

(1) a coil cutting through a magnetic field, or
(2) a magnetic field cutting through a coil.

As long as there is relative motion between a conductor and a magnetic field, a voltage will be induced in the conductor.

That part of a generator that produces the magnetic field is called the field.
That part in which the voltage is induced is called the armature.

For relative motion to take place between the conductor and the magnetic field, all generators must have two mechanical parts - a rotor and a stator. The ROTor is the part that ROTates; the STATor is the part that remains STATionary. In a dc generator, the armature is always the rotor. In alternators, the armature may be either the rotor or stator.


Making AC electricity

When a wire is moved in the magnetic field of a generator, the movement, magnetic field and current are all at right angles to each other. If the wire is moved in the opposite direction, the induced current also moves in the opposite direction.

Remember that one side of a coil in a generator moves up during one half turn, and then down during the next half turn.

This means that as a coil is rotated in a magnetic field, the induced current reverses direction every half turn. This is called alternating current (AC).

It is different from the direct current (DC) produced by a battery, which is always in the same direction.



In practical generators, the coil is fixed, and mounted outside the magnet, and it is the magnet which moves.

The size of the induced voltage can be increased by:

* rotating the coil or magnet faster
* using a magnet with a stronger magnetic field
* having more turns of wire in the coil
* having an iron core inside the coil

The mains electricity is an AC supply. The voltage it supplies to our homes is 230V.


Transformers

A transformer is an electrical device that changes the voltage of an ac supply. A transformer changes a high-voltage supply into a low-voltage one, or vice versa.

* A transformer that increases the voltage is called a step-up transformer.
* A transformer that decreases the voltage is called a step-down transformer.
* Step-down transformers are used in mains adapters and rechargers for mobile phones and CD players.
* Transformers do not work with dc supplies.

A transformer consists of a pair of coils wound on an iron core. The AC in one coil produces a changing magnetic field. This changing magnetic field induces a voltage in the other coil of the transformer.

How transformers work

A transformer needs an alternating current that will create a changing magnetic field. A changing magnetic field also induces a changing voltage in a coil. This is the basis of how a transformer works:

  • The primary coil is connected to an AC supply.
  • An alternating current passes through a primary coil wrapped around a soft iron core.
  • The changing current produces a changing magnetic field.
  • This induces an alternating voltage in the secondary coil.
  • This induces an alternating current (AC) in the circuit connected to the secondary coil.

It's important to know that:

  • There is no electrical connection between the primary and the secondary coils.
  • Transformers only work if AC is supplied to the primary coil. If DC was supplied, there would be no current in the secondary coil.
  • As the current in the primary coil increases steadily or decreases steadily, there is a constant voltage induced in the secondary coil.
  • As the voltage in the primary coil reaches maximum strength the voltage induced in the secondary coil is at its weakest (zero volts).

Calculating voltages

The ratio between the voltages in the coils is the same as the ratio of the number of turns in the coils.

primary voltage / secondary voltage = turns on primary / turns on secondary

This can also be written as:

Vp/Vs = Np/Ns

Step-up transformers have more turns on the secondary coil than they do on the primary coil.

Step-down transformers have fewer turns on the secondary coil than they do on the primary coil.



Question

A transformer has 20 turns on the primary and 400 on the secondary. What is the output voltage if the input voltage is 500V?

Answer:

Vp/Vs = Np/Ns Therefore Vs/Vp = Ns/Np

Vs/500 = 400/20

Vs = 500 x (400/20)

Vs= 10,000 Volts




Ideal power equation

If the secondary coil is attached to a load that allows current to flow, electrical power is transmitted from the primary circuit to the secondary circuit. Ideally, the transformer is perfectly efficient; all the incoming energy is transformed from the primary circuit to the magnetic field and into the secondary circuit.

If this condition is met, the incoming electric power must equal the outgoing power:



giving the ideal transformer equation





Transformers normally have high efficiency, so this formula is a reasonable approximation.

If the voltage is increased, then the current is decreased by the same factor. The impedance in one circuit is transformed by the square of the turns ratio.[29]

For example, if an impedance Zs is attached across the terminals of the secondary coil, it appears to the primary circuit to have an impedance of (Np/Ns)2Zs. This relationship is reciprocal, so that the impedance Zp of the primary circuit appears to the secondary to be (Ns/Np)2Zp.


Transmission

Electricity is generated on a large scale at power stations and then transmitted through cables (called the National Grid) to factories and homes.

Copper cables carrying the electricity are buried in the ground or aluminium cables are suspended from pylons. Aluminium is used because it has a low density
and can safely be suspended from inexpensive thin pylons. Pylons have the disadvantage that they look ugly on the landscape but have the advantage of easy access to the cables for maintenance and repair. Transmission using pylons is cheaper than burying cables underground.

Transformers are used to produce a very high voltage for the transmission of electricity, to minimize energy loss.

A generator at a power station might produce electricity with a voltage of 25,000V and a current of 8,000A.

Such a large current would cause the cables of the National Grid to get hot because of the heating effect of current.

Energy could be lost due to :

1. heat loss due to resistance in coils
2. leakage of magnetic field lines between primary and secondary coils
3. heat loss due to eddy currents induced in iron core
4. hysteresis loss caused by the flipping of magnetic dipoles in the iron core due to the a.c.

To reduce the energy loss, a step up transformer at the power station is used to raise the voltage to 400,000V.This is 16 times the input voltage of 25,000V.

Sunday, January 2, 2011

Motor Coil Forces

Electric Motor

Look at the single coil of wire below. It is connected to a DC supply. Current flows, as shown by the red arrows.



Use Fleming's Left Hand Rule to show that the left and right hand sides of the coil experience a force up and down.

Using the Left Hand Rule, you should work out that the wire experiences the following forces:



As a result, it will rotate clockwise. Let's see what will happen next.

When the coil moves into the vertical postition (as long as the current is still flowing) the forces acting on the wires remain :



The forces act against each other: the coil will stop rotating! How then can a real motor keep going in the same direction? And how does it not twist its wires into a mess?

The Commutator

The answer is to use a commutator. This device prevents the wires from twisting. More importantly it actually allows the coil to keep rotating in one direction!



The one shown is a split-ring commutator. It has two halves, each connected to the power supply, completing the coil circuit. The coil is able to turn smoothly around it.

The commutator is made from two round pieces of copper, one on each side of the spindle. A piece of carbon (graphite) is lightly pushed against the copper
to conduct the electricity to the armature. The carbon brushes against the copper when the commutator spins.

In the vertical position there is no current as the coil has lost its connections to the commutator. Since the coil was already moving, it keeps turning. Think about riding a bike - stop pedalling and you don't stop moving for quite some time.

As the motor rotates, first one piece of copper, then the next connects with the brush every half turn. The wire on the left side of the armature always has current flowing in the same direction, and so the armature will keep turning in the same direction.



The pieces of copper are held apart in the centre and do not touch each other.
They look like a ring of copper which is split down the middle. This is why it is called a split - ring commutator.

Summary points: split-ring commutators reverse the direction of the current in the coil each half turn. This allows the motor coil to rotate continuously in one direction.

To increase the turning effect of the coil in the motor:

1.Insert a soft Iron core or cylinder into coil - to concentrate the magnetic field lines.

2. Increase the number of turns in the coil.

3. Increase the current in the coil.